Internal Modem Connections

ION 7500 / ION 7600 User’s Guide

Page 132

Chapter 5 - Features and Applications

Internal Modem Connections

Refer to the “Hardware Reference” chapter for internal modem specifications for
the ION 7500 and ION 7600 meters.

This section only applies if your meter has an internal modem option. Depending
on the ION meter and its date of manufacture, the installed optional internal
modem could be one of two different brands. The Conexant modem is the older
type modem, and is available in North American (FCC approved) or European
(CTR-21 compliant) versions. The newer modem is manufactured by Multi-Tech
and is a universal modem that can be readily used in most countries, and complies
with FCC, Industry Canada and TBR-21 regulations — refer to the Notices at the
start of this document for more details.

The internal modem shares the communications channel with the optical port. It is
factory-configured to respond (and the optical port is disabled). To enable
communications through the meter’s internal modem, you must configure the
Comm 3 Communications module. The Baud Rate, Unit ID, and Protocol setup
registers must properly match your system, and the initialization string for the
internal modem must be set up using the ModemInit register.

N

OTE

The internal modem is multiplexed with the IrDA optical port on the meter’s front panel, so only one
channel can be in use at a time. To use the modem, the

Comm Mode

setup register of the Comm 3

Communications module must be set to Modem (the default value).

ModemInit Setup Register

The ModemInit string register defines the initialization string for the internal
modem, with a maximum of 47 characters. Edit the ModemInit register and enter
the initialization string desired. The string is sent to the modem as soon as you
download the COM1 module. Note that the string is also sent to the modem
whenever the meter is powered up, or whenever the baud rate in the Comm 1
Communications module is changed. Any changes to the Modem Init or Baud Rate
setup registers while the modem is online will cause the modem to disconnect
from the phone line.

C

AUTION

Changing the

ModemInit

setup register while the internal modem is online causes the modem to

disconnect from the phone line.