Overview of Security

Two separate layers of ION security protect your power monitoring system from
unsolicited changes or tampering: ION software security and ION meter security.
Each type of security has its own password protection scheme. An optional
hardware lock security is also available for revenue meters.

Icon Descriptions

You will encounter the following security-related icons within ION meters and
ION software.

This icon refers to ION software security. See “ION Enterprise
Software Security” on page 251 and “ION Set
up Software
Security” on page 253
.

This icon refers to ION meter security. See “Standard Meter
Security” on page 255
and “Advanced Meter Security (ION
8000 Series)” on page 258.

◆

Requires a password separate from ION

software password

◆

Capable of Standard and Advanced Security

◆

Requires valid user name and password when

starting any ION software component

◆

Logon provides your security access level,

which in turn determines the manner of con-

figuration changes you can make

◆

Password-enabled access is separate from

meter security

◆

You must still provide the meter’s password to

make any configuration changes

ION Software Security

ION Meter Security

Logged-on User changes meter

configuration via ION software

Meter requests its own password

before accepting change

Standard

◆

Requires single

password with no

username

◆

Enabled by default

on all

ION meters

◆

Meter password

still required for

changes made

using software

Advanced

◆

Available on ION

8000 Series meters

only

◆

Up to 16 different

users allowed, each

user has unique

access rights

◆

Requires both user-

name and password

Optional: Hardware Lock Security

◆

Meter is physically locked

◆

Denies any changes to revenue-related

parameters

◆

Must break the lock and place the meter in

TEST mode to change revenue related

modules