6 connecting to external instruments, Connecting to external instruments -4, 6 connecting to external instru- ments – Yokogawa ADMAG AXF User Manual

Page 11

Advertising
background image

IM 1E10C1-E

3-4

3. INSTALLATION

Please slope the conduit pipe down, and install a drain
valve at the low end of the vertical pipe.

Please open the drain valve regularly.

Drain valve

F030207.EPS

Figure 3.2.7

Conduit Wiring

3.2.6

Connecting to External Instru-
ments

CAUTION

All the devices to be connected to current
output and pulse output must be conformed to
CSA1010, CSA950, or IEC950.

(1)Analog Signal Output(4 to 20mADC)

ADMAG SE

RECEIVER

CUR+

CUR–

F030208.EPS

+

+

Load Resistance
max. 600

Figure 3.2.8

Connection for Analog Singal Output

(2)Pulse Output

IMPORTANT

Please give attention to voltage and polarity in
wiring, because it is transister contact (insula-
tion type.)

• In case of the filtering constant of Electric

Counter is more than the pulse width, it makes
signal decreases and can not be calculated
correctly.

• In case of input impedance of electric counter

is large inductive noise from power supply
bring bad influence to measurement. To
calculate correctly, it is recommended to use
shield cable or to make input impedance small
enough within the limits of pulse output of
flowmeter.

ADMAG SE

PULSE OUT

PLS/ALM+

PLS/ALM–

+

Protective diode

30 V DC, 0.2A. max*

*In case of FM Nonincendive type, 0.135A max.

Mechanical counter

ADMAG SE

PULSE OUT

PLS/ALM+

+

Universal counter or

Electronic counter

Load

PLS/ALM–

F030209.EPS

Figure 3.2.9

Pulse Output Connection

(3)Alarm or Status Output

IMPORTANT

This is a transistor contact(insulated type) so
attention must be paid to voltage and polarity
when making connections.
This output can not switch an AC load. To do
this, another relay (see the figure below) is
required.

* The alarm output works from "close"(Normal) to

"open"(Alarm).

ADMAG SE

ADMAG SE

PLS/ALM+

PLS/ALM–

PLS/ALM+

PLS/ALM–

Load

Protective diode

This connection cannot be made.

Magnetic

valve

AC power supply

F030210.EPS

External

Power supply

30 V DC, 0.2A. max*

*In case of FM Nonincendive type, 0.135A max.

Figure 3.2.10 Contact Output Connection