Normal operating condition, Terminal connection, Accessories – Yokogawa ADMAG AXF User Manual

Page 91: Model and suffix code, Caution

Advertising
background image

IM 1E10C1-E

10-2

10. OUTLINE

Maximum Power Consumption:

11W for SE***DJ/EJ+SE14

Insulation Resistance:

• 100M

between power terminals and ground

terminal at 500V DC.
• 100M

between power terminals and each

output terminal at 500V DC.
• 20M

between each output terminal (except

for EX1 and EX2) and ground terminal at 100V
DC.
• 20M

between (EX1 or EX2) and ground ter-

minal at 50V DC.

Withstand Voltage:

• 1500V AC between power terminals and
ground terminal for 1 minute. (for -A1/A2 power
supply)
• 500V AC between power terminals and ground
terminal for 1 minute. (for -D1 power supply)

CAUTION

When performing the Voltage Breakdown Test,
Insulation Resistance Test or any unpowered
electrical test, wait 10 seconds after the power
supply is turned off before removing the housing
cover. Be sure to remove the Short Bar at terminal
“G”. After testing, return the Short Bar to its correct
position. Screw tightening torque should be 1.18N-
m(0.88ft-lb)or more, because the G-terminal is
thought as a protective grounding and should
conform to the Safety Requirements.

Safety Requirement Standard:

IEC1010, EN61010

EMC Conformity Standard:

EN61326
EN61000-3-2, EN61000-3-3
AS/NZS 2064

NORMAL OPERATING CONDITION

Ambient Temperature: -20 to 60

°

C (-4 to 140

°

F)

Ambient Humidity: 5 to 95%RH (no condensation)
Rated Power Supply Voltage:

100V AC/DC Version:
Range 80 to 127V AC, 47 to 63Hz

90 to 110V DC

230V AC Version: Range 180 to 264V AC
24V DC/AC Version:
Range 20.4 to 28.8 V DC/AC

Supplied Power and Max. Cable Length for 24V

DC version:

Allowable cable length m(ft)

1000(3300)

900(2970)

800(2640)

700(2310)

600(1980)

500(1650)

400(1320)

300(990)

200(660)

100(330)

0

20

22

24

26

28

(V)

Cable cross section area: 1.25 mm

2

Cable cross section area: 2 mm

2

F01.EPS

Altitude at installation side:

Max.2000m above sea level

Installation category based on IEC1010:

II (See Note)

Pollution level based on IEC1010: 2(See Note)

Note: • The “Installation category” implies the regulation for

impulse withstand voltage. It is also called the
“Overvoltage category”.“II” applies to electrical
equipment.

• “Pollution level” describes the degree to which a

solid, liquid or gas which deteriorates dielectric
strength is adhering. “2” applies to a normal indoor
atmosphere.

Fuse: 2A 250V (Time-Lag type)

TERMINAL CONNECTION

Terminal
Symbols

Description

SA

A
B

SB

C

EX1
EX2

P+

P-

I+

I-

L/+

N/-

G

Flow signal input

T03-1.EPS

Protective grounding

A shield

Current output 4 to 20mA DC

Excitation current output

B shield
Common

Pulse, alarm or status output

Power supply and

Ground

PLS/ALM
OUT

CUROUT

POWER
SUPPLY

ACCESSORIES

Data sheet

1

Unit labels sheet

1

Hexagonal wrench

1

(for special screw of terminal cover/display cover.)
Plug 1 (in case of DC power supply version)

Mounting bracket

1set

MODEL AND SUFFIX CODE

Magnetic Flow Converter:

T05.EPS

Model

Suffix code

Description

SE14

Magnetic Flow Converter

Aux.Cod -J.........................

Always J

Output

D .....................
E .....................

4-20mA and Pulse or Alarm, Simultaneous 2-output (BRAIN)
4-20mA and Pulse or Alarm, Simultaneous 2-output (HART)

Indicator

NN ...............
H1 ................
H2 ................

Non Indicator
With Indicator
With Indicator and Setting SW

Power Supply -A1 .............

-A2 .............
-D1 ............

80 to 127V AC / 90 to 110 VDC
180 to 264 V AC
20.4 to 28.8V DC/AC

Electrical Connection
(Refer to Note1)

0 ......
2 ......
3 ......
4 ......

/ ...

JIS G1/2 Female
ANSI 1/2NPT Female
DIN Pg 13.5 Female
ISO M20X1.5 Female

Optional Codes

...........................

Note1 : Only ANSI 1/2NPT electrical connection is available for FM or CSA explosion proof type.
JIS G1/2 electrical connection is not available for any explosion proof type.

Dedicated Signal Cable:

Model

Suffix Code

Description

AM011

..............................

-0 ..........................
-4 ..........................

Dedicated cable for magnetic
flowmeter

Non termination
Terminated

Enter the length in m (Max 300m)

Style A

Number of end treatment parts

-L .........

*A ............

/C ..

End
treatment

Cable length

Style code

Optional specification

T10.EPS

Note 1 : A user provided two conductor cable is required for coil excitaiton.
Note 2 : The maximum temperature for the signal cable is 80

؇

C(176

؇

F).