3 parameters, 1 parameters configuration, 2 data renewing – Yokogawa ADMAG AXF User Manual

Page 58: Parameters -8, Parameters configuration -8, Data renewing -8

Advertising
background image

IM 1E10C1-E

7-8

7. OPERATION VIA HART COMMUNICATOR

7.3 Parameters

7.3.1

Parameters Configuration

Parameters of HART Communicator is constructed hierarchically. The menu tree for
Online menu is shown in 7.3.3 Menu Tree.

See “Chapter 11. Parameter List” about the usage of each parameter. Note the differ-
ences between parameters on ADMAG SE display and those on HART Communicator.

The Online menu summary is shown below.

Table 7.1.3Online Menu Summary

No.

Display Item

Contents

1

2

3

4

Device setup

PV

PV AO

SPAN

Set parameters for ADMAG SE.

Display process value in engineering unit.

Display analog output in mA.

Display set span in engineering unit.

7.3.2

Data Renewing

There are two methods to load the data of ADMAG SE from/to HART Communicator,
periodic data renewing and discretionary data renewing.

(1) Periodic Data Renewing

The follwing data are renewed in 0.5 to 2 seconds cycle.

PV, PV AO, PV % rnge, Totl, Reverse total, Diff. total, Power freq, Velocity
check

(2) Discretionary Data Renewing

The following data can be loaded from/to ADMAG SE. Up load can be done with
SAVE (F2) on any online menu, and down load can be done on Saved Configuration
menu in Offline menu. (Refer to HART Communicator Manual.)

Descriptor, Message, Date, Tag, Span, Line size, Size unit, PV Damp, Base vol
unit, Base time unit, Disp select, Fl user sel, Fl user span, Total unit, Total scale,
Total low cut, Tl set value, Total set, Analog low cut, Analog low lmt, Analog hi
lmt, Analog alarm out, Output function, Pulse unit, Pulse scale, Pulse low cut,
Pulse width.

The changed data with HART Communicator is sent to ADMAG SE by pressing
SEND (F2) of HART Communicator.

NOTE