7. OPERATION VIA HART COMMUNICATOR

(6) Trim Analog Output

Fine output adjustment is carried out with “D/A trim” or “Scaled D/A trim”.

D/A Trim

D/A trim” is to be carried out if the calibration digital ammeter does not read 4.000
mA and 20.000 mA exactly with the output signal of 0% and 100%.

Scaled D/A Trim

Scaled D/A trim” is to be carried out if the output is adjusted using a voltmeter or
other types of meters with 0% to 100% scale.

1. Device setup

2. Diag/Service

1. Test device

4. Output trim

ADMAG SE :
Output trim
1 D/A trim
2 Scaled D/A trim

HELP

SAVE

HOME

ENTER

1

2

Select “D/A trim”.

Press OK (F4).

Connect the ammeter (

±

1

µ

A is measurable.), and press OK

(F4).

Press OK (F4), and the ADMAG SE outputs the output signal
of 0%.

Ammeter reading: 4.115

Enter the read value “4.115” of the ammeter, and press
ENTER (F4).
(The output of the ADMAG SE changes.)

ADMAG SE :
Connect reference
meter

HELP

SEND

ABORT

OK

3

Call up “Output trim” display.

ADMAG SE :
WARN-Loop should be
removed from
automatic control

DEL

DEL

ABORT

OK

ADMAG SE :
Setting fld dev
output to 4mA

DEL

DEL

ABORT

OK

4

F4

5

(ENTER)

‘4.115’

ADMAG SE :
Enter meter value
4.0000

HELP

DEL

ABORT

ENTER

F4

(OK)

F4

(OK)

F4

(OK)

Example 1: For the adjustment using an ammeter (

±

1uA is measurable.)