Argument – ADLINK PCI-8164 User Manual
Page 192
![background image](/manuals/733467/192/background.png)
180
Function Library
Visual Basic (Windows 95/NT/2K/XP)
B_8164_set_pls_outmode (ByVal AxisNo As Integer,
ByVal pls_outmode As Integer) As Integer
B_8164_set_pls_iptmode (ByVal AxisNo As Integer,
ByVal pls_iptmode As Integer, ByVal
pls_logic As Integer) As Integer
B_8164_set_feedback_src (ByVal AxisNo As Integer,
ByVal Src As Integer) As Integer
@ Argument
AxisNo: The designated axis number to configure pulse Input/
Output.
pls_outmode: Setting of command pulse output mode
pls_iptmode: setting of encoder feedback pulse input mode
pls_logic: Logic of encoder feedback pulse
X
pls_logic=0, Not inverse direction
X
pls_logic=1, Inverse direction
Value
Meaning
Notes
0
OUT/DIR OUT Falling edge, DIR+ is high level
1
OUT/DIR OUT Rising edge, DIR+ is high level
2
OUT/DIR
OUT Falling edge, DIR+ is low level
3
OUT/DIR
OUT Rising edge, DIR+ is low level
4
CW/CCW
Falling edge
5
CW/CCW
Rising edge
6
4XA/B
Falling edge
7
4XA/B
Rising edge
Value Meaning
0
1X A/B
1
2X A/B
2
4X A/B
3
CW/CCW