ADLINK PCI-8164 User Manual
Page 258
![background image](/manuals/733467/258/background.png)
246
Function Library
CmpSrc: The comparing source counter
X
CmpSrc =0, Command Counter
X
CmpSrc =1, Feedback Counter
X
CmpSrc =2, Error Counter
X
CmpSrc =3, General Counter
CmpMethod: The comparing method
X
CmpMethod =0, No compare
X
CmpMethod =1, CmpValue=Counter (Directionless)
X
CmpMethod =2, CmpValue=Counter (+Dir)
X
CmpMethod =3, CmpValue=Counter (-Dir)
X
CmpMethod =4, CmpValue>Counter
X
CmpMethod =5, CmpValue<Counter
X
CmpMethod =6, Reserved
CmpAction: The reacting mode when comparison comes into
exist
X
CmpAction =0, INT and Internal sync. signal output
X
CmpAction =1, Immediate stop
X
CmpAction =2, Slow down then stop
X
CmpAction =3, Speed change
Data: Comparing value
TriggerType: Selection of type of trigger output mode
X
Hardware Version A2
Z
TriggerType =0, one shoot (default)
Z
TriggerType =1, constant high
X
Hardware Version A3
Z
TriggerType =0, normal high (default)
Z
TriggerType =1, normal low