ADLINK PCI-8164 User Manual

Page 258

Advertising
background image

246

Function Library

CmpSrc: The comparing source counter

X

CmpSrc =0, Command Counter

X

CmpSrc =1, Feedback Counter

X

CmpSrc =2, Error Counter

X

CmpSrc =3, General Counter

CmpMethod: The comparing method

X

CmpMethod =0, No compare

X

CmpMethod =1, CmpValue=Counter (Directionless)

X

CmpMethod =2, CmpValue=Counter (+Dir)

X

CmpMethod =3, CmpValue=Counter (-Dir)

X

CmpMethod =4, CmpValue>Counter

X

CmpMethod =5, CmpValue<Counter

X

CmpMethod =6, Reserved

CmpAction: The reacting mode when comparison comes into

exist

X

CmpAction =0, INT and Internal sync. signal output

X

CmpAction =1, Immediate stop

X

CmpAction =2, Slow down then stop

X

CmpAction =3, Speed change

Data: Comparing value

TriggerType: Selection of type of trigger output mode

X

Hardware Version A2

Z

TriggerType =0, one shoot (default)

Z

TriggerType =1, constant high

X

Hardware Version A3

Z

TriggerType =0, normal high (default)

Z

TriggerType =1, normal low