The MPC-8164 card is PC104-compliant. The onboard DIP
switches and jumpers assign the card’s I/O port locations and IRQ
channels.

A single-board setup has a default setting of 0x200 and IRQ5. In
GEME systems, the default value varies depending on the location
of the card. Refer to the following table:

Table 2-1: GEME hardware configuration

Base address setting

The base address is set by SW1 (pins 2 to 4). Note that pin 1 is
reserved. If all DIPs are set to OFF, the base address is 0x200.
Default settings are dependent on the order.

Table 2-2: Base Addresses

GEME level Base address IRQ

1

0x300

9

2

0x200

5

3

0x280

10

DIP Switch (2 3 4) Base Address DIP Switch (2 3 4) Base Address

1 1 1

0x3C0

1 1 0

0x2C0

0 1 1

0x380

0 1 0

0x280

1 0 1

0x340

1 0 0

0x240

0 0 1

0x300

0 0 0

0x200