Function Library

245

@ Argument

AxisNo_2or3: Axis number, for last two axes in one card

ltc_logic: 0 means active low, 1 means active high

AxisNo: Axis number

LatchNo: Specified Counter to latch

X

LatchNo = 1 , Command counter

X

LatchNo = 2 , Feedback counter

X

LatchNo = 3 , Error Counter

X

LatchNo = 4 , General Counter

Pos: Latched counter value,

PLimit: Soft limit value, positive direction

NLimit: Soft limit value, negative direction

Action: The reacting method of soft limit

X

Action =0, INT only

X

Action =1, Immediately stop

X

Action =2, Slow down, then stop

X

Action =3, Reserved

Tolerance: The tolerance of step-losing detection form 0 - 32767

On_Off: Enable/Disable step-losing detection

X

On_Off =0, Disable

X

On_Off =1, Enable

CompNo: The comparator number of axis

X

CompNo =1, Comparator1, default for positive soft limit

X

CompNo =2, Comparator2, default for negative soft limit

X

CompNo =3, Comparator3, default for for position error
check

X

CompNo =4, Comparator4, It could be any counter source

X

CompNo =5, Comparator5, default for triggering output