ADLINK PCI-8164 User Manual

Page 225

Advertising
background image

Function Library

213

@ Argument

AxisNo: Designated axis number to configure and perform home

return

home_mode: Stopping modes for home return, 0-12

X

(Please refer to section 4.1.8)

org_logic: Action logic configuration for ORG

X

org_logic=0, active low

X

org_logic=1, active high

EZ_logic: Action logic configuration for E

X

EZ_logic=0, active low

X

EZ_logic=1, active high

ez_count: 0-15 (Refer to section 4.1.8)

erc_out: Set ERC output options

X

erc_out =0, no erc out;

X

erc_out =1, erc out when home finishing

StrVel: starting velocity of a velocity profile in units of pulse per

second

MaxVel: starting velocity of a velocity profile in units of pulse per

second

Tacc: specified acceleration time in units of seconds

ORGOffset: The escape pulse amounts when home search

touches the ORG singal

@ Return Code

ERR_NoError

Advertising