5 ramping-down and pcs, Ramping-down and pcs – ADLINK PCI-8164 User Manual

Page 60

Advertising
background image

48

Signal Connections

3.5 Ramping-down and PCS

There is a SD/PCS signal for each of the 4 axes. The signal
names, pin numbers, and axis numbers are shown in the table
below.

A circuit diagram is shown below. Typically, the limit switch is used
to generate a slow-down signal to drive motors operating at slower
speeds. For more details on SD/PCS operation, refer to section
4.3.1.

CN2 Pin No Signal Name Axis #

40

SD1/PCS1

1

46

SD2/PCS2

2

90

SD3/PCS3

3

96

SD4/PCS4

4