5 ramping-down and pcs, Ramping-down and pcs – ADLINK PCI-8164 User Manual
Page 60
Advertising
48
Signal Connections
3.5 Ramping-down and PCS
There is a SD/PCS signal for each of the 4 axes. The signal
names, pin numbers, and axis numbers are shown in the table
below.
A circuit diagram is shown below. Typically, the limit switch is used
to generate a slow-down signal to drive motors operating at slower
speeds. For more details on SD/PCS operation, refer to section
4.3.1.
CN2 Pin No Signal Name Axis #
40
SD1/PCS1
1
46
SD2/PCS2
2
90
SD3/PCS3
3
96
SD4/PCS4
4
Advertising