1.1.3 Encoder monitoring

HEIDENHAIN contouring controls can monitor the signal transmissions of the measuring system.
This measuring system monitoring must be activated by a machine parameter.
Three different conditions can be checked:

Error message

The absolute position of distance-coded reference marks

C

The amplitude of the measuring system signals

A

The edge separation of the measuring system signals

B

If one of the conditions is not fulfilled, it results in the error message:

"Measuring system <axis> defect A/B/C."

For sinusoidal signals the LE monitors the amplitude of the measuring system signals, for square-
wave signals the LE evaluates the fault detection signal (U

aS

) of the external electronics (EXE or

IBV).

MP30

Checking the absolute position of the distance-coded reference marks
Input range: 0 to 15

Bit 0

X axis

+0 = not active
+1 = active

Bit 1

Y axis

+0 = not active
+2 = active

Bit 2

Z axis

+0 = not active
+4 = active

Bit 3

4th axis

+0 = not active
+8 = active

MP31

Checking the amplitude of the measuring system signals
Input range: 0 to 31

Bit 0

X axis

+0 = not active
+1 = active

Bit 1

Y axis

+0 = not active
+2 = active

Bit 2

Z axis

+0 = not active
+4 = active

Bit 3

4th axis

+0 = not active
+8 = active

Bit 4

Axis S

+0 = not active
+16 = active