3.8 Measuring with a 3D touch probe
Machine
parameter
Function and input
Reaction /
CN 123
Page
MP6010
Selection of the touch probe system
Input: 0 or 1
0 = TS 120
1 = TS 511
CN 123
4-152
MP6120
Probing feed rate
Input range: 80 to 30 000 [mm/min]
CN 123
4-152
MP6130
Maximum measuring range
Input range: 0.001 to 99 999.999 [mm]
CN 123
4-152
MP6140
Safety clearance above measuring point
Input range: 0.001 to 99 999.999 [mm]
CN 123
4-152
MP6150
Rapid traverse for probe cycle
Input range: 80 to 30 000 [mm/min]
CN 123
4-152
3.9 Digitizing with TS 120 (only with digitizing option)
Machine
parameter
Function and input
Reaction /
CN 123
Page
MP6210
Number of oscillations per second in normal
direction
Input range: 0 to 65.535 [1/s]
4-156
MP6230
Feed rate in normal direction
Input range: 0 to 10 000 [mm/min]
4-156
MP6240
Maximum deflection of stylus
Input range: 0 to 10.000 [mm]
4-156
MP6250
Numerical value for M function for transferring
modal values
Input 0 to 89
0 = no transfer
1 ... 89 number of the M function
4-157
MP6260
Output of M90 for NC blocks with digitized data
Input: 0 or 1
0 = no output of M90
1 = output of M90 in every NC block
4-157
MP6270
Rounding of trailing zeros
Input: 0 to 1
0 = Output in 0.001 mm increments (1
µ
m)
1 = Output in 0.01 mm increments (10
µ
m)
4-157