5-16

TNC 360

3 List of Machine Parameters

4/96

3.8 Measuring with a 3D touch probe

Machine
parameter

Function and input

Reaction /
CN 123

Page

MP6010

Selection of the touch probe system
Input: 0 or 1

0 = TS 120
1 = TS 511

CN 123

4-152

MP6120

Probing feed rate
Input range: 80 to 30 000 [mm/min]

CN 123

4-152

MP6130

Maximum measuring range
Input range: 0.001 to 99 999.999 [mm]

CN 123

4-152

MP6140

Safety clearance above measuring point
Input range: 0.001 to 99 999.999 [mm]

CN 123

4-152

MP6150

Rapid traverse for probe cycle
Input range: 80 to 30 000 [mm/min]

CN 123

4-152

3.9 Digitizing with TS 120 (only with digitizing option)

Machine
parameter

Function and input

Reaction /
CN 123

Page

MP6210

Number of oscillations per second in normal
direction
Input range: 0 to 65.535 [1/s]

4-156

MP6230

Feed rate in normal direction
Input range: 0 to 10 000 [mm/min]

4-156

MP6240

Maximum deflection of stylus
Input range: 0 to 10.000 [mm]

4-156

MP6250

Numerical value for M function for transferring
modal values
Input 0 to 89
0 = no transfer
1 ... 89 number of the M function

4-157

MP6260

Output of M90 for NC blocks with digitized data
Input: 0 or 1
0 = no output of M90
1 = output of M90 in every NC block

4-157

MP6270

Rounding of trailing zeros
Input: 0 to 1
0 = Output in 0.001 mm increments (1

µ

m)

1 = Output in 0.01 mm increments (10

µ

m)

4-157