HEIDENHAIN TNC 335 Technical Manual User Manual
Page 377

6-8
TNC 360
1 List of Markers
8/95
Marker
Function
Set
Reset
Page
M2800
to
M2807
Key code
PLC
PLC
7-124
M2808
Strobe marker for key code
PLC
PLC
7-124
M2809
Activate numerical value transfer from PLC to NC
PLC
PLC
7-124
M2810
Data format of a numerical value in M2560 to M2576
7-124
M2811
Data format of a numerical value in M2560 to M2576
7-124
M2812
Data format of a numerical value in M2560 to M2576
7-124
M2813
Activate the key from W516
PLC
NC
4-139
M2814
Activation of a gear range and spindle speed via PLC
PLC
NC
4-86
M2815
Flashing PLC error message
PLC
PLC
4-122
M2816
Select traverse range
PLC
PLC
4-16
M2817
Select traverse range
PLC
PLC
4-16
M2818
Q number (msb)
PLC
PLC
7-124
M2819
Activate datum correction
PLC
NC
7-124
M2824
Activation of the selected traverse range
(M2816/M2817)
PLC
NC
4-16
M2825
External EMERGENCY OFF via PLC
PLC
PLC
–
M2826
Suppress handwheel pulses
PLC
PLC
4-167
M2827
Suppress EMERGENCY OFF, open the control loop, NC stop
PLC
PLC
–
M2829
NC block generation
PLC
NC
4–121
M2832
to
M2839
Key code of the pressed inhibited key
NC
NC
7-124
M2855
to
M2923
Inhibit keys
PLC
PLC
4-142
M2924
to
M3023
Activate PLC error messages
PLC
NC;
PLC
4-122
M3168
Overflow during multiplication
NC
PLC
7-59
M3169
Division by 0
NC
PLC
7-60
M3170
MODULO incorrectly executed
NC
PLC
7-61
M3171
M3171 is set when transfer incorrectly executed
7-103
- 118
M3172
Reserved for errors that the PLC programmer would like to
intercept
–
M3200
to
M3263
Values from MP4310.3 to MP4310.6
7-125