Touch probe system input, Connector assignment, 8 touch probe system input – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 55: 1 connector assignment x12
Advertising

3-28
TNC 360
8 Touch Probe System Input
8/95
8 Touch Probe System Input
The 3D touch probe systems from HEIDENHAIN can be delivered in two versions:
– TS 120 with cable transmission and integrated APE interface electronics
– TS 511 with infrared transmission of the trigger signal and connectable via APE interface
electronics
For start-up and adjustment of the 3D touch probe systems see Chapter "Machine Integration".
8.1 Connector assignment
X12
X12 Touch probe system TS 120/TS 511
Flange socket with female connector insert (15-pin)
Pin Number
Signal designation
1
Inner screen (0 V)
3
Ready/standby
4
Start
5
+15 V ± 10 % (U
P
)
6
+ 5 V ± 5 % (U
P
)
7
Battery warning
8
0 V (U
N
)
9
Trigger signal
10
Trigger signal
2
2, 11 to 15
Do not use
2 Stylus in rest position = signal high
Advertising