HEIDENHAIN TNC 335 Technical Manual User Manual
Page 372

4/96
TNC 360
1 List of Markers
6-3
Marker
Function
Set
Reset
Page
M2096
X key last pressed
NC
NC
4-113
M2097
Y key last pressed
NC
NC
4-113
M2098
Z key last pressed
NC
NC
4-113
M2099
Key IV last pressed
NC
NC
4-113
M2100
X axis is tool axis
NC
NC
4-13
M2101
Y axis is tool axis
NC
NC
4-13
M2102
Z axis is tool axis
NC
NC
4-13
M2103
4th axis is tool axis
NC
NC
4-13
M2104
G Code S Analog 1st bit (lsb)
PLC
PLC
4-86
M2105
G Code S Analog 2nd bit
PLC
PLC
4-86
M2106
G Code S Analog 3rd bit (msb)
PLC
PLC
4-86
M2112
T Number (P Number) 1st decade (lsb)
7-124
M2113
T Number (P Number) 1st decade
7-124
M2114
T Number (P Number) 1st decade
7-124
M2115
T Number (P Number) 1st decade (msb)
7-124
M2116
T Number (P Number) 2nd decade (lsb)
7-124
M2117
T Number (P Number) 2nd decade
7-124
M2118
T Number (P Number) 2nd decade
7-124
M2119
T Number (P Number) 2nd decade (msb)
7-124
M2128
X axis in motion
NC
NC
4-76
M2129
Y axis in motion
NC
NC
4-76
M2130
Z axis in motion
NC
NC
4-76
M2131
4th axis in motion
NC
NC
4-76
M2136
X axis reference mark not yet traversed
NC
NC
–
M2137
Y axis reference mark not yet traversed
NC
NC
–
M2138
Z axis reference mark not yet traversed
NC
NC
–
M2139
4th axis reference mark not yet traversed
NC
NC
–
M2149
Strobe marker for Q parameter transfer with FN19
NC
NC
–
M2150
Unit of measure of the NC program (0 = mm, 1 = inch)
NC
NC
–
M2160
Traverse direction X axis
0 = positive 1 = negative
NC
NC
4-7
M2161
Traverse direction Y axis
0 = positive 1 = negative
NC
NC
4-7
M2162
Traverse direction Z axis
0 = positive 1 = negative
NC
NC
4-7
M2163
Traverse direction 4th axis
0 = positive 1 = negative
NC
NC
4-7
M2176
Code operating mode (lsb)
7-124
M2177
Code operating mode
7-124
M2178
Code operating mode
7-124
M2179
Code operating mode (msb)
7-124
M2180
1st PLC scan after switch-on
NC
NC
–
M2182
Inhibited key was operated
NC
PLC
4-141
M2183
Program interruption
("Control operational" display flashes)
NC
NC
4-118
M2184
Control operational
("Control operational" display goes on or flashes)
NC
NC
4-118
M2185
1st PLC scan after interruption of the PLC program
NC
NC
–
M2186
Code number 84159 entered
NC
PLC
7-124
M2190
Non-flashing error message is displayed
NC
NC
4-122
M2191
"External EMERGENCY STOP" message is displayed
NC
NC
4-106