Positioning, 2 positioning – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 352

5-8
TNC 360
3 List of Machine Parameters
4/96
Machine
parameter
Function and input
Reaction /
CN 123
Page
MP920.0
to
MP920.3
Neg. software limit switch for traverse range 1:
Input range:
–99 999.999 to +99 999.999 [mm] or [°]
4-15
MP921.0
to
MP921.3
Neg. software limit switch for traverse range 2:
Input range:
–99 999.999 to +99 999.999 [mm] or [°]
4-15
MP922.0
to
MP922.3
Neg. software limit switch for traverse range 3:
Input range:
–99 999.999 to +99 999.999 [mm] or [°]
4-16
MP950.0
to
MP950.3
Datum point for positioning blocks with M92
Input range:
–99 999.999 to +99 999.999 [mm] or [°]
Values referenced to machine datum
4-110
3.2 Positioning
Machine
parameter
Function and input
Reaction /
CN 123
Page
MP1010.0
to
MP1010.3
Rapid traverse
Input range: 80 to 300 000 [mm/min]
4-56
MP1020.0
to
MP1020.3
Manual feed
Input range: 80 to 300 000 [mm/min]
4-56
MP1030.0
to
MP1030.3
Positioning window
Input range: 0.001 to 2 [mm] or [°]
4-72
MP1040
Polarity of the nominal value voltage for the
positive direction of traverse
Input range: 0 to 15
Bit 0
X axis
+0 = positive
+1 = negative
Bit 1
Y axis
+0 = positive
+2 = negative
Bit 2
Z axis
+0 = positive
+4 = negative
Bit 3
4th axis +0 = positive
+8 = negative
4-7
MP1050.0
to
MP1050.3
Analog voltage for rapid traverse
Input range: 4.5 to 9 [V]
4-56
MP1060.0
to
MP1060.3
Acceleration
Input range: 0.001 to 3.0 [m/s
2
]
4-54
MP1070
Radial acceleration
Input range: 0.001 to 3.0 [m/s
2
]
4-66
MP1080.0
to
MP1080.3
Integral factor
Input range: 0 to 65 535
4-64