8/95

TNC 360

11 PLC inputs/outputs

3-51

PLC outputs

Assignment of the grouped power supply:

Terminal

Assignment PL 410 /PL 410 B

X9

0 V

X10

+24V PL supply and "Control is ready" (cannot be
switched of via EMERGENCY STOP)

X11

+24 V supply

O32 - O39

X12

+24 V supply

O40 - O47

X13

+24 V supply

O48 - O55

X14

+24 V supply

O56 - O62

Pin Layout

X7

X8

Pin Number

Assignment PL 410/PL
410 B

Pin Number

Assignment PL 410/PL
410 B

1

O32

1

O48

2

O33

2

O49

3

O34

3

O50

4

O35

4

O51

5

O36

5

O52

6

O37

6

O53

7

O38

7

O54

8

O39

8

O55

9

O40

9

O56

10

O41

10

O57

11

O42

11

O58

12

O43

12

O59

13

O44

13

O60

14

O45

14

O61

15

O46

15

O62

16

O47

16

"Control is operational"