HEIDENHAIN TNC 335 Technical Manual User Manual
Page 336

8/95
TNC 360
16 Commissioning and Start-up Procedure
4-239
Optimizing transient response
MP1530 affects the form of the acceleration ramp in all axes .
U [V]
t [ms]
Tacho
voltage
MP1530 correct
MP1530 too large
MP1530 too small
Since MP1530 is effective for all axes, the worst axis determines the entry value. No axis should
show an overshoot.
Connect storage oscilloscope to
tachometer of servo-amplifier of X axis.
Enter following program in
"PROGRAMMING AND EDITING"
operating mode:
LBL 1
X 100
1)
R0 F MAX
X 0 R0 F MAX
CALL LBL 1 REP 100/100
Press machine START button in the
"PROGRAM RUN/SINGLE BLOCK"
operating mode.
Machine runs.
MP1530: Increase entry value until overshoot occurs.
MP1530: Reduce entry value until overshoot stops.
U [V]
t [ms]
Check axes Y, Z and IV and correct MP1530, if necessary.
U [V]
t [ms]
1)
Program the traverse paths for the axis concerned as large as possible.