HEIDENHAIN TNC 335 Technical Manual User Manual
Page 335

4-238
TNC 360
16 Commissioning and Start-up Procedure
8/95
Optimizing acceleration
If the maximum acceleration of the servo loop cannot be determined with the battery supply, the
acceleration can be optimized as follows:
No
Yes
Enter following values for
position supervision
MP1410: 0.5
MP1420: 30
MP1060
Increase "acceleration"
in small steps.
Press machine START button in the
"PROGRAM RUN/FULL SEQUENCE"
operating mode.
Enter the 0.7 to 0.9-fold factor of
the determined values
as acceleration in MP1060.
Enter following program in
"PROGRAMMING AND EDITING"
operating mode:
LBL 1
X 100
1)
R0 F MAX
X 0 R0 F MAX
CALL LBL 1 REP 100/100
Control stops machine.
Error display
"POSITIONING ERROR"
?
Connect storage oscilloscope to
tachometer of servo-amplifier of X axis.
Enter acceleration from MP1060.0
in MP1060.1 to 1060.4.
Move the Y, Z and IV axes with
the acceleration value found.
Reduce values, if necessary.
1)
Program the traverse paths for the axis concerned as large as possible.