2 hardware – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 22

9/93
TNC 360/TNC 335
Update information No. 1
1-7
Potential errors:
A non-existent axis was transferred.
An axis was transferred that was not configured in MP10 and MP60 as an auxiliary axis.
The axis is already moving.
Call:
PS
B/W/D/K <Axis>
(0 to 3 for X/Y/Z/4)
PS
B/W/D/K <Feed rate>
(mm/min)
PS
B/W/D/K <Flag register>
Bit 0
= 1: negative traverse direction
= 0: positive traverse direction
CM9123
PL
B/W/D
<Error code>
0: Positioning was started
1: A non-existent axis was transferred
2: The axis is not configured as an auxiliary axis
3: The axis is already moving
Error status after call: M3171
= 0: Positioning was started
= 1: Faulty execution
2 Hardware
The part numbers of the LE 360C logic units that can accommodate 2M byte EPROMs are:
Id.-Nr. 270 641 3x for BE 212
Id.-Nr. 270 642 3x for BF 110
The 2-M byte EPROMs occupy only the sockets IC-P1 and IC-P2. IC-P3 and IC-P4 remain vacant.
The jumper located next to IC-P1 should then be inserted in the setting 2M!
You will receive Update Information issues on the TNC 360/TNC 335 hardware and software
whenever developments warrant. This information will then be included in Supplementary Issues
that you can integrate into the appropriate chapters of the Technical Manual.