2.3 Humidity

Permissible humidity:

< 75 % in continuous operation,
< 95 % for not more than 30 days p.a. (randomly distributed).

In tropical areas it is recommended that the TNC is not switched off, so that condensation is avoided
on the circuit boards. The heat generation prevents condensation and has no further disadvantages.

2.4 Mechanical vibration

Permissible vibration:

< 0.5 g

2.5 Mounting position

Note the following fundamental points on mounting:

– Mechanical accessibility
– Permissible environmental conditions
– Electrical noise immunity
– The electrical regulations in effect in your country