HEIDENHAIN TNC 335 Technical Manual User Manual

Page 326

Advertising
background image


8/95

TNC 360

16 Commissioning and Start-up Procedure

4-229

U [V]

t [ms]

U

max

Incorrect!

Too flat

Incorrect

The P component of the subordinate control loop is too low, or the I component too high.

Determination of the acceleration

The maximum acceleration time T can be deduced from the step response.

U [V]

t [ms]

U

max

T

To calculate the acceleration increase T by 10%.

From this it follows that:

a =

v

T

max

.

11

v

max

= convert velocity at U

max

in [m/sec]

a = acceleration [sec]

T = Acceleration time [sec]

The step response must be investigated for all axes.
The acquired acceleration values are entered in MP1060.0 to MP1060.3.
After adjustment, switch off the supply voltage to the drive amplifiers.
This concludes the preparation of the drive amplifiers.