HEIDENHAIN TNC 335 Technical Manual User Manual
Page 5

1-2
TNC 360
Update Information No. 8
4/96
MP7670
Interpolation factor for handwheel
Input:
0 to 10
MP7670.0
Interpolation factor for low speed
MP7670.1
Interpolation factor for medium speed
MP7670.2
Interpolation factor for high speed
MP7671
Manual feed rate in "handwheel" operating mode with HR 410
Input:
0 to 1000 [% to MP1020]
MP7670.0
Low speed
MP7670.1
Medium speed
MP7670.2
High speed
A dummy plug (Id.-Nr. 271 958 03) is available for an EMERGENCY STOP.
There are connecting terminals on the adapter for the contacts from the emergency stop button
and the permissive buttons (maximum load 1.2 A)
Connector layout:
VL ID number 281 429..
KA ID number 296 466..
VB ID number 296 467 05
HR 410
ID number
296 469 01
D-sub
connector
(male
)
9-pin
D-sub
connector
(female
)
9-pin
D-sub
connector
(male
)
9-pin
Coupling on
mounting
base
(female)
18-pin
Connecto
r (male
)
18-pin
Connecto
r (female)
18-pin
Connecto
r (male)
18-pin
Housing
Shield
Housing
Housing
Shield
Housing
Housing
Shield
Housing
Housing
Shield
2
White
2
2
White
E
E
White
E
E
4
Brown
4
4
Brown
D
D
Brown
D
D
6
Yellow
6
6
Yellow
B
B
Yellow
B
B
7
Gray
7
7
Gray
A
A
Gray
A
A
8
Green
8
8
Green
C
C
Green
C
C
6
6
WH/BK
6
6
7
7
YL/BK
7
7
5
5
WH/RD
5
5
4
4
WH/BL
4
4
2
2
WH/GN
2
2
3
3
WH/YL
3
3
1
1
WH/BR
1
1
WH/BR
3
Contacts 1 + 2
WH/YL
2
Contact 2 (left) Permissive button
WH/GN
1
Contact 1 (right)
WH/BL
1
Contact 1
WH/RD
2
Contact 1 Emergency stop
YL/BK
3
Contact 2
WH/BK
4
Contact 2