9 adjust the offset, 10 adjustment of the monitoring functions – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 340

8/95
TNC 360
16 Commissioning and Start-up Procedure
4-243
16.3.9 Adjust the offset
The rough offset adjustment has already been carried out on the servo amplifier. A fine offset
adjustment can be performed with the offset adjustment possibility described in Section "Servo
positioning".
16.3.10 Adjustment of the monitoring functions
The following entry values are recommended for the monitoring functions (see Section "Servo
positioning"):
Machine parameter Function
Entry value
MP1710
Position monitoring
1.2
×
lag in rapid traverse
MP1720
Position monitoring (EMERGENCY STOP)
1.4
×
lag in rapid traverse
MP1410
Position monitoring
0.5 [mm]
MP1420
Position monitoring (EMERGENCY STOP)
10 [mm]
MP1140
Movement monitoring
0.5 [V]
MP1030
Positioning window
0.01 [mm]
MP1110
Standstill monitoring
0.2 [mm]
If the drives of the machine permit narrower limits, these may be entered.