Timers and counters, 1 timers, 4 timers and counters 2.4.1 timers – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 396

8/95
TNC 360
2 Program Creation
7-17
Address
Function
W960
Value from MP 4220.0
W962
Value from MP 4220.1
W964
Value from MP 4220.2
W966
Value from MP 4220.3
W968
Value from MP 4220.4
W976
Value from MP 4310.0
W978
Value from MP 4310.1
W980
Value from MP 4310.2
W982
Value from MP 4310.3
W984
Value from MP 4310.4
W986
Value from MP 4310.5
W988
Value from MP 4310.6
MP4210.0
Set a number in the PLC
to MP4210.47
Input range: –99 999.999 to +99 999.999
MP 4220
Setting a number in the PLC: In the Word range W960 to W968
to MP4220.4
Input range: 80 to 30 000
MP4230.0
Set a number in the PLC via module 9032
to MP4230..31
Input range: –30 000 000 to +30 000 000
to
MP4239.0
to MP4239.31
MP4310.0
Set a number in the PLC: in the Word range W976 to W988
to MP4310.6
Input range: 0 to 65 535
2.4 Timers and counters
2.4.1 Timers
48 timers are available in the PLC. These 48 timers are controlled by special markers with the
abbreviation symbol T. The time period for the timer is defined in the machine parameter MP4110.X.
The time unit corresponds to the PLC cycle time.
The timers are started by setting the markers T0 to T47 which also sets the timers to the value from
MP4110.X. This activation may only be performed for a single PLC run, as otherwise the timers will
be restarted by every succeeding run.
The markers T48 to T95 (timer running) will remain set for the period defined in the machine
parameters.