2 plc output – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 67
Advertising

3-42
TNC 360
11 PLC inputs/outputs
8/95
11.2.2 PLC output
The PLC outputs O0 to O30 and the "Control is operational" output are on connector X21 (PLC
output). The PLC outputs O0 to O7 are also to be found on the connector for the machine control
panel (X27).
See also Section "Machine control panel".
X21 PLC output
D-sub connector (37-pin female insert)
Pin Number
Assignment
1
O0
2
O1
3
O2
4
O3
5
O4
6
O5
7
O6
8
O7
9
O8
10
O9
11
O10
12
O11
13
O12
14
O13
15
O14
16
O15
17
O16
18
O17
19
O18
20
O19
21
O20
22
O21
23
O22
24
O23
25
O24
1)
26
O25
1)
27
O26
1)
28
O27
1)
29
O28
1)
30
O29
1)
31
O30
1)
32
Do not use
33
0 V (PLC)
1)
34
Control operational
Housing
Outer screen
1) Cannot be switched off via EMERGENCY STOP