1 Introduction
9-5
MP7240
Inhibit program input for [Program number] = [OEM-cycle number in
EPROM].
Input value 0 or 1
0 = inhibit
1 = not inhibit
MP7250
Difference between Q-parameter number for "CALL-active" and "DEF-active"
block in OEM cycles
Input range: 0 to 50
MP7251
Number of global Q parameters transferred from OEM-cycle to calling
program.
Input range: 0 to 100
OEM cycles stored in the PLC EPROM can be inhibited in the PLC program via flags M2240 to
M2271. Inhibited cycles cannot be defined in NC programs.
If programs with definitions of inhibited or non-existent OEM cycles are transferred to the control
unit, an error message "PGM 999999.. UNAVAILABLE" is generated during program call. The
program cannot be run.
Flag
Function
Set
Reset
M2240
Inhibit OEM-cycle 68
PLC
PLC
M2241
Inhibit OEM-cycle 69
PLC
PLC
M2242
Inhibit OEM-cycle 70
PLC
PLC
.
.
.
.
.
.
M2271
Inhibit OEM-cycle 99
PLC
PLC