HEIDENHAIN TNC 335 Technical Manual User Manual

Page 557

Advertising
background image

8/95

TNC 360

1 Introduction

9-5

MP7240

Inhibit program input for [Program number] = [OEM-cycle number in
EPROM].
Input value 0 or 1
0 = inhibit
1 = not inhibit

MP7250

Difference between Q-parameter number for "CALL-active" and "DEF-active"
block
in OEM cycles
Input range: 0 to 50

MP7251

Number of global Q parameters transferred from OEM-cycle to calling
program.
Input range: 0 to 100

OEM cycles stored in the PLC EPROM can be inhibited in the PLC program via flags M2240 to
M2271. Inhibited cycles cannot be defined in NC programs.

If programs with definitions of inhibited or non-existent OEM cycles are transferred to the control
unit, an error message "PGM 999999.. UNAVAILABLE" is generated during program call. The
program cannot be run.

Flag

Function

Set

Reset

M2240

Inhibit OEM-cycle 68

PLC

PLC

M2241

Inhibit OEM-cycle 69

PLC

PLC

M2242

Inhibit OEM-cycle 70

PLC

PLC

.

.

.

.

.

.

M2271

Inhibit OEM-cycle 99

PLC

PLC