HEIDENHAIN TNC 335 Technical Manual User Manual
Page 350

5-6
TNC 360
3 List of Machine Parameters
4/96
Machine
parameter
Function and input
Reaction /
CN 123
Page
MP110.0
to
MP110.3
Assignment of the measuring system inputs
to the axes
Input range: 0 to 5
0 = measuring system input X1
1 = measuring system input X2
2 = measuring system input X3
3 = measuring system input X4
5 = measuring system input X6
RESET
4-12
MP120.0
to
MP120.3
Assignment of the nominal value outputs
Input range: 0 to 5
0 = output 1
1 = output 2
2 = output 3
3 = output 4
5 = output S
RESET
4-13
MP210
Count direction of the measuring system signals
Input range: 0 to 15
Bit 0
X axis
+0 = positive
+1 = negative
Bit 1
Y axis
+0 = positive
+2 = negative
Bit 2
Z axis
+0 = positive
+4 = negative
Bit 3
4th axis +0 = positive
+8 = negative
RESET
4-7
MP310
Signal subdivision
Input range: 0 to 3
0 = 256-fold
1 = 4-fold
2 = 2-fold
3 = 1-fold
4-6
MP330.0
to
MP330.3
Signal period
Input range 1000 to 1000,000 in [
µ
m] or
[
1°
1000
]
REF
4-6
MP340.0
to
MP340.4
Interpolation factor of the EXE at X6
Input: 0 to 5
0 = No measuring system on X6
1 = EXE without interpolation
2 = Spindle encoder with 2048 lines
3 = Spindle encoder with 4096 lines
5 = EXE with 5-fold interpolation
4-6