Machine
parameter

Function and input

Reaction /
CN 123

Page

MP110.0
to
MP110.3

Assignment of the measuring system inputs
to the axes
Input range: 0 to 5

0 = measuring system input X1
1 = measuring system input X2
2 = measuring system input X3
3 = measuring system input X4
5 = measuring system input X6

RESET

4-12

MP120.0
to
MP120.3

Assignment of the nominal value outputs
Input range: 0 to 5

0 = output 1
1 = output 2
2 = output 3
3 = output 4
5 = output S

RESET

4-13

MP210

Count direction of the measuring system signals
Input range: 0 to 15

Bit 0

X axis

+0 = positive
+1 = negative

Bit 1

Y axis

+0 = positive
+2 = negative

Bit 2

Z axis

+0 = positive
+4 = negative

Bit 3

4th axis +0 = positive

+8 = negative

RESET

4-7

MP310

Signal subdivision
Input range: 0 to 3

0 = 256-fold
1 = 4-fold
2 = 2-fold
3 = 1-fold

4-6

MP330.0
to
MP330.3

Signal period

Input range 1000 to 1000,000 in [

µ

m] or

[

1000

]

REF

4-6

MP340.0
to
MP340.4

Interpolation factor of the EXE at X6
Input: 0 to 5

0 = No measuring system on X6
1 = EXE without interpolation
2 = Spindle encoder with 2048 lines
3 = Spindle encoder with 4096 lines
5 = EXE with 5-fold interpolation

4-6