Plc i/o expansion-board, 1 pl 400 connection, 4 plc i/o unit – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 69
Advertising

8/95
TNC 360
11 PLC inputs/outputs
3-45
11.4 PLC I/O unit
One PL 400 board with 63 PLC inputs, 31 PLC outputs and the "Control is operational" output can be
connected to the logic unit. The PL 400 can be mounted directly on the logic unit. See Section
"Power supply" for the power connection.
11.4.1 PL 400 connection
Pin connections on the logic unit
X26 PLC I/O board (PL 400)
D-sub connector (24-pin male insert)
Pin Number
Assignment
1, 2, 3
0 V
4
Serial IN 2
5, 6, 17, 18
Do not use
7
RESET
8
WRITE EXTERN
9
WRITE EXTERN
10
A5
11
A3
12
A1
13
Screen
14, 15, 16
+ 12 V (from PL 400)
19
Serial IN 1
20
EMERGENCY STOP
21
Serial OUT
22
Serial OUT
23
A4
24
A2
25
A0
Housing
External shield