6 control is operational – HEIDENHAIN TNC 335 Technical Manual User Manual

Page 215

Advertising
background image


4-118

TNC 360

6 Display and Operation

8/95

The machine parameter MP 7235 allows a specific resetting of the run duration timers.

MP7235

Resetting the timing
Input value: 0 to 7

Bit 0

Run time – Control on
+0 cannot be reset
+1 can be reset

Bit 1

Run time – Program run
+0 cannot be reset
+2 can be reset

Bit 2

Run time – Spindle
+0 cannot be reset
+4 can be reset

It is not possible to reset a timer during a program run.

6.3.6 Control is operational

If the control is operational, i.e. a positioning or M function is performed, the status window displays
a large asterisk "*". If a current NC program is interrupted with the external stop key, a "*" will flash
in the status display. This information is transmitted to the PLC through the markers M2183 and
M2184. M2183 and M2184 are effective in the operating modes "Positioning with MDI", "Program
run, single block" and "Program run, full sequence."

Set

Reset

M2183

Program interruption (display "Control is ready"

NC

NC

flashes)

M2184

Control is ready ("Control is ready" display
goes on or flashes)