Power supply, Overview, Nc power supply – HEIDENHAIN TNC 335 Technical Manual User Manual

Page 43: 4 power supply 4.1 overview, 1 nc power supply

Advertising
background image


3-14

TNC 360

4 Power Supply

8/95

4 Power Supply

4.1 Overview

The supply voltages must meet the following specifications:

Unit

Supply voltage

Voltage range dc
average

Max. current
consumption

Power
consumption

LE

NC

24 Vdc
(VDE 0160, 5.88
low-voltage
electrical
separation)

Lower limit
20.4 V

- - -

LE 360 1.5 A

28.8 ... 36 W
(also supplies
the BE 212)

Upper limit

PLC

24 Vdc
(VDE 0160, 5.88
base insulation)

31 V

- - -

1)

2 A
when half

3

) of

the outputs are
switched on
simultaneously

Approx. 48 W
when half

3

) of

the outputs are
switched on
simultaneously

PL 410 B
PL 410

4

)

PL 400

4

)

20 A
when half

3

) of

the outputs are
switched on
simultaneously

Approx. 480 W
when half

3

) of

the outputs are
switched on
simultaneously

HRA 110

(VDE 0160, 5.88
low-voltage
electrical
separation)

0.2 A

Approx. 5 W

BF 110

2)

Approx. 1 A with
full display

24 W typical
32 W max.

1

) Voltage surges up to 36 V

- - -

permissible for t< 100 ms.

2

) The BF 110 has its own line power connection, which also powers the internal ventilation.

3

) No more than half the outputs can be switched on simultaneously.

4

) No longer included in product program

4.1.1 NC power supply

Connection terminal X31

Pin Number

Assignment

1

+ 24 Vdc

2

0 V