8/95

TNC 360

11 PLC inputs/outputs

3-43

11.3 Connecting cable

Please use only HEIDENHAIN connecting cables.

The length of cable between the logic unit and the element to be switched is limited to 25 m.
HEIDENHAIN recommends building a transfer unit with a terminal strip into the switch cabinet.
This transfer unit can be connected to the logic unit with the HEIDENHAIN connecting cable Id.-Nr.
244 017 ..

max. 25 m

Id.-Nr. 244 017..

If operation is to be without transfer unit, then the HEIDENHAIN connecting cable
Id.-Nr. 244 005 .. can be used.

max. 25 m

Id.-Nr. 244 005..

Terminal color assignments:

1

=

GY/RD

14

=

GN/BL

27

=

YL/BK

2

=

BN/BK

15

=

YL

28

=

WH/YL

3

=

WH/BK

16

=

RD

29

=

GY/BL

4

=

GN/BK

17

=

GY

30

=

PK/BL

5

=

BN/RD

18

=

BL

31

=

PK/RD

6

=

WH/RD

19

=

PK

32

=

BN/BL

7

=

WH/GN

20

=

WH/GY

33

=

PK/GN

8

=

RD/BL

21

=

YL/GY

34

=

BN

9

=

YL/RD

22

=

GN/RD

35

=

YL/PK

10

=

GY/PK

23

=

WH/PK

36

=

VI

11

=

BK

24

=

GY/GN

37

=

WH

12

=

PK/BN

25

=

YL/BN

13

=

YL/BL

26

=

GY/BN

If the connector is to be assembled in the field, a 37-pin solderable connector is available from
HEIDENHAIN (Id.-Nr. 243 937 ZY).

Advertising