Yaskawa MP2000 Series I/O Module User Manual User Manual

Page 107

Advertising
background image

4.3 LIO-06 Module Details

4.3.3 Counter Module Configuration

107

4

LIO-06 Module

[ b ] In (Input) Data Details

The following table provides details of the In Data Area.

Œ

Abbreviated names are given in square brackets in the Name column.

No.

Register

No.

Name

Contents

Range

Unit

Size

IW††00

*1

Status
(Run Status)
[RUNSTS]

The run status of the Counter Module is
indicated for each bit.
When online:

: ON ( = 1 ),

: OFF ( = 0 ),

When off line:

1 word

Bit 0

Error Setting the Data
(Data setting error)

Bit 1

Fixed Parameter Error

Bit 2

Preset Count Completed

Bit 3

PI Latch Completed

Bit 4

A/B Pulse 0
(Feedback pulse is ±1 or less)

Bit 5

Coincidence Detection

Bit 6

A-Pulse Status Monitor

Bit 7

B-Pulse Status Monitor

Bit 9

Fixed Parameter Write

Bit A

A-Pulse Disconnection

Bit B

B-Pulse Disconnection

Bit C

POSMAX Preset
(POSMAX turns presetting
completed)

Bit F

Module Ready

01

IL††02

Incremental Pulses
[PDV]

Indicates the difference between the pulse
count value at previous scan and that at
present scan.

-2147483648
to 2147483647

pulse

2 words

02

IL††04

Counter Value [PFB] Indicates the pulse count value of each scan.

-2147483648
to 2147483647

pulse

2 words

03

IL††06

PI Latch Value
[FREQ]

Indicates the current value of the counter
when an external signal is input.

-2147483648
to 2147483647

pulse

2 words

04

IL††08

After Convert Incre-
ment Pulse [PDVG]

Indicates the number of incremental pulses
converted to a value in the reference unit.
Indicates the same value as the number of
incremental pulses if pulse is selected for
the fixed parameter No. 08 “Reference Unit
Selection” (when the electronic gear is not
used).

-2147483648
to 2147483647

Refer-

ence

unit

2 words

05

IL††0A

Current Count Val-
ue After Converts
[PFBG]

Indicates the current value of the counter
converted to a value in the reference unit.
Indicates the same value as the counter cur-
rent value when pulse is selected for the
fixed parameter No. 08 “Reference Unit
Selection” (when the electronic gear is not
used).

-2147483648
to 2147483647

Refer-

ence

unit

2 words

06

IL††0C

PI Latch Value After
Converts [FREQG]

Indicates the PI latch data converted to a
value in the reference unit. Indicates the
same value as the PI latch data when pulse
is selected for the fixed parameter No. 08
“Reference Unit Selection” (when the elec-
tronic gear is not used).

-2147483648
to 2147483647

Refer-

ence

unit

2 words

07

IL††0E

Number of POSMAX
Turns

Indicates the number of rotations that have
been made when Infinite Length Axis is
selected for the fixed parameter No. 07
“Axis Selection.”

-2147483648
to 2147483647

Rota-

tion

2 words

Advertising