1 outline of lio-06 module, 1 outline of functions – Yaskawa MP2000 Series I/O Module User Manual User Manual

Page 86

Advertising
background image

4.1 Outline of LIO-06 Module

4.1.1 Outline of Functions

86

4.1 Outline of LIO-06 Module

4.1.1 Outline of Functions

The LIO-06 Module is I/O Modules having digital I/O, analog I/O, and pulse counter functions. There are 8 digital
inputs (DI) and 8 digital outputs (DO) (sink mode outputs) for the digital I/O function, and 1 analog input (AI) channel
and 1 analog output (AO) channel for the analog I/O function. There is also 1 pulse input (PI) channel for the pulse
counter function.
Digital I/O, analog I/O, and pulse input are made at a periodical cycle for each high-speed scan or low-speed scan of
the MP2000 Series Machine Controller. The following diagram outlines the functions of the LIO-06 Module.

Fig. 4.1 Outline of LIO-06 Module Functions

4.1.2 LIO-06 Module Appearance and Connector External Dimensions

The following figure shows the appearance of the LIO-06 Module and the connector external dimensions.

Output
processing

FUSE blown
detection

Coincidence
output

Pulse
input
processing

Latch
input

Input
processing

Interrupt
input

Input port
(Isolated DI)

5-V differential
A/B input

Coincidence
interrupt

5-V/12-V/24-V
Z input

8 points

8 points

DI-00

DI-01

DO-07

System bus

Analog input
processing

Analog output
processing

DO-00 to 07

Output port
(Isolated DO)

I/O connector

LIO-06

ALM

RUN

CN1

LED indicators

I/O connector

Unit

㧦mm

41

95

19.3

125

Advertising