2.3 LIO-01/LIO-02 Module Details

50

* 1. IW††00 gives the register number that is displayed in The First Register Number cell on the Fix Parameter Set

Tab Page + 00.

* 2. The Feedback Speed is the moving average of the results of the following calculation for 32 scans.

Œ

Without Electronic Gear (Reference unit: Pulse)
Feedback Speed (pulse/s) = No. of incremental pulses

× 1000)/Ts

Œ

With Electronic Gear (Reference unit: Unit other than pulse)
Feedback Speed (reference unit/s) = No. of incremental pulses after conversion

× 1000)/Ts

TS: Scan time (ms) for counter synchronized scan.

* 3. Refer to 2.5 Electronic Gear Function on page 59.

01

IL††02

Incremental Pulses
[PDV]

Indicates the difference between the pulse
count value at previous scan and that at
present scan.

-2147483648
to 2147483647

pulse

2 words

02

IL††04

Counter Value [PFB] Indicates the pulse count value of each scan.

-2147483648
to 2147483647

pulse

2 words

03

IL††06

PI Latch Value
[FREQ]

Indicates the current value of the counter
when an external signal is input.

-2147483648
to 2147483647

pulse

2 words

04

IL††08

After Convert Incre-
ment Pulse [PDVG]

Indicates the number of incremental pulses
converted to a value in the reference unit.
Indicates the same value as the number of
incremental pulses if pulse is selected for
the fixed parameter No. 08 “Reference Unit
Selection” (when the electronic gear is not
used).

-2147483648
to 2147483647

Refer-

ence

unit

2 words

05

IL††0A

Current Count Val-
ue After Converts
[PFBG]

Indicates the current value of the counter
converted to a value in the reference unit.
Indicates the same value as the counter cur-
rent value when pulse is selected for the
fixed parameter No. 08 “Reference Unit
Selection” (when the electronic gear is not
used).

-2147483648
to 2147483647

Refer-

ence

unit

2 words

06

IL††0C

PI Latch Value After
Converts [FREQG]

Indicates the PI latch data converted to a
value in the reference unit. Indicates the
same value as the PI latch data when pulse
is selected for the fixed parameter No. 08
“Reference Unit Selection” (when the elec-
tronic gear is not used).

-2147483648
to 2147483647

Refer-

ence

unit

2 words

07

IL††0E

Number of POSMAX
Turns

Indicates the number of rotations that have
been made when Infinite Length Axis is
selected for the fixed parameter No. 07
“Axis Selection.”

-2147483648
to 2147483647

Rota-

tion

2 words

08

IL††10

Feedback Speed

*2

If the electronic gear

*3

is not used, the unit

is pulse/s.

-2147483648
to 2147483647

Refer-

ence

unit

2 words

09

IL††1E

System Monitor

For system use

-2147483648
to 2147483647

2 words

(cont’d)

No.

Register

No.

Name

Contents

Range

Unit

Size

Advertising