4.3 LIO-06 Module Details

4.3.3 Counter Module Configuration

109

4

LIO-06 Module

[ c ] Out (Output) Data Details

The following table shows details of the Out Data Area.

Œ

Abbreviated names are given in square brackets in the Name column.

* 1. OW††00 gives the register number that is displayed in The First Register Number cell on the Fix Parameter

Set Tab Page + 00.

* 2. Refer to 4.4.4 PI Latch Function on page 115.
* 3. Refer to 4.4.3 Coincidence Output and Coincidence Interrupt Functions on page 114.

No.

Register

No.

Name

Contents

Range

Unit

Size

OW††00

*1

Operation Mode
(RUN Mode)
[RUNMOD]

Bit 0

Count Disable

ON (=1): Counting prohibited
OFF (=0): Counting enabled
(Default)
Prohibits counting while the bit is
ON (=1).

1

word

Bit 1

Calculating Preset

(Count Preset Request)
ON (=1): Request preset
OFF (=0): Not requested (Default)
Resets the count to its preset value
when the bit is turned ON (=1).

Bit 2

PI Latch Detect Demand

*2

ON (=1): Request latch detection
OFF (=0): Not requested (Default)
Stores the counter value at the
moment an external signal is input
while the bit is ON (=1).

Bit 3

Coincidence Detection

*3

ON (=1): Request coincidence detec-
tion
OFF (=0): Not requested (Default)
Sends a coincidence signal if the val-
ues of the counter and the coinci-
dence detection setting match when
the bit is turned ON (=1).

Bit 4

POSMAX Presetting

(POSMAX Turns Presetting
Request)
ON (=1): Requests preset
OFF (=0): Not requested (Default)
Resets the number of POSMAX turns
to its preset value when the bit turns
ON (=1).

OW††01

Set Function/
Latch Detection
Signal

Select the external signal to be used for the PI
latch signal.

• 0001H: DI latch (discrete input)
• 0002H: Z latch (phase-Z input)

0001H to
0002H

1

word

01

OL††02

Count Presetting
Data [PRSDAT]

The current value of the counter is reset to
this value when a Count Preset Request is
output.

-2147483648
to 2147483647

Reference
units

2

words

02

OL††04

Agreed Detection
Value (Coinci-
dence Detection
Set Value)
[COINDAT]

A coincidence detection signal and an inter-
rupt signal to the MP2000 Series Machine
Controller are output if the current value of
the counter equals the value set in this param-
eter when the Coincidence Detection Request
is output.

-2147483648
to 2147483647

Reference
units

2

words

03

OL††06

Preset Data of
POSMAX Turns

The number of POSMAX turns is reset to the
value set in this parameter when a POSMAX
Turn Number Presetting Request is output.

-2147483648
to 2147483647

Rotations

2

words

04

OL††1E System Monitor

For system use.