Setting menu table – Panasonic AV-UHS500 12G-SDI/HDMI UHD 4K Compact Live Switcher User Manual

Page 178

Advertising
background image

178

Menu

Sub menu

Parameter 1

Parameter 2

Parameter 3

Parameter 4

Use [F1] to select.

Use [F2] to select. Use [F3] to select. Use [F4] to select. Use [F5] to select.

Config

GPI-In Port2/2

Parameter

Port5 Assign

Port6 Assign

Port7 Assign

Port8 Assign

Setting range

The setting range is the same as for the GPI-In Port1/2 sub menu.

Default value

No Assign

No Assign

No Assign

No Assign

GPI-Out
Setting

Parameter

GPI-Out Enable AUX Tly Sel

Setting range

On, Off

AUX1, AUX2,
AUX3, AUX4

Default value

On

AUX1

GPI-Out
Port1/5

Parameter

Port1 Assign

Port2 Assign

Port3 Assign

Port4 Assign

Setting range

No Assign, AUTO, CUT, KEY1 ON, KEY2 ON, KEY3 ON, DSK1 ON,
DSK2 ON, FTB ON, BKGD AUTO, BKGD CUT, KEY1 AUTO, KEY2
AUTO, KEY3 AUTO, KEY1 CUT, KEY2 CUT, KEY3 CUT, Red Tly 1

to

13, GRN Tly 1

to

13, AUX Tly 1

to

13, Event MEM

Default value

No Assign

No Assign

No Assign

No Assign

GPI-Out
Port2/5

Parameter

Port5 Assign

Port6 Assign

Port7 Assign

Port8 Assign

Setting range

The setting range is the same as for the GPI-Out Port1/5 sub menu.

Default value

No Assign

No Assign

No Assign

No Assign

GPI-Out
Port3/5

Parameter

Port9 Assign

Port10 Assign

Port11 Assign

Port12 Assign

Setting range

The setting range is the same as for the GPI-Out Port1/5 sub menu.

Default value

No Assign

No Assign

No Assign

No Assign

GPI-Out
Port4/5

Parameter

Port13 Assign

Port14 Assign

Port15 Assign

Port16 Assign

Setting range

The setting range is the same as for the GPI-Out Port1/5 sub menu.

Default value

No Assign

No Assign

No Assign

No Assign

GPI-Out
Port5/5

Parameter

Port17 Assign

Port18 Assign

Port19 Assign

Setting range

The setting range is the same as for the GPI-Out Port1/5
sub menu.

Default value

No Assign

No Assign

No Assign

System Menu

Parameter

Lock

Setting range

On, Off

Default value

Off

Key Source
Signal
Coupling1

Parameter

Fill/Source

Setting range

Fill To Source,
Source To Fill

Default value

Fill To Source

Key Source
Signal
Coupling2

Parameter

IN1

IN2

SDI IN3

SDI IN4

Setting range

IN1, IN2, SDI IN3, SDI IN4, SDI IN5, SDI IN6, SDI IN7, SDI IN8, IN-
A1, IN-A2, IN-A3, IN-A4, IN-B1, IN-B2, IN-B3, IN-B4, Black, CBGD 1,
CBGD 2, CBAR, Still 1V, Still 1K, Still 2V, Still 2K, Clip 1V, Clip 1K,
Clip 2V, Clip 2K

Default value

IN1

IN2

SDI IN3

SDI IN4

Key Source
Signal
Coupling3

Parameter

SDI IN5

SDI IN6

SDI IN7

SDI IN8

Setting range

The setting range is the same as for the Key Source Signal Coupling2 sub
menu.

Default value

SDI IN5

SDI IN6

SDI IN7

SDI IN8

Setting menu table