Basic operations

Linking the key fill signal and key source signal
selection

1

Press the KEY button to be used to display the menu.
(KEY1/KEY2/KEY3)

2

Use [F1] to display the Key Signal Coupling sub menu
and set Independent.

3

Press the

CONF

SYS

button to light its indicator, and display

the Config menu.

4

Use [F1] to display the Key Signal Coupling1 sub menu
and set Fill/Source.

5

Use [F1] to display the Key Signal Coupling2 to 8 sub
menu.

p

If Key Signal Coupling1 is Fill to Source, select what to
use as the Source for the Fill.

p

Alternatively, if it is Source to Fill, select what to use as
the Fill for the selected Source.

<Independent>
When the [KEY] button lights in amber, the key fill signal
can be selected, and when it lights in green, the key
source signal can be selected.

Independent

ON

If Fill to Source, you can independently set
a Source that is linked to Fill and separate
from other KEYs.
If Source to Fill, you can independently set
a Fill that is linked to Source and separate
from other KEYs.

OFF

Settings accord with Key Signal Coupling2
to 8.

<Fill To Source>
When the key fill signal is selected, the key source
signal also switches automatically.
Initially, the key source signal and the key fill signal will
be the same signal.
For example, when “SDI1” is selected for the key fill
signal, the key source signal also becomes “SDI1”.
After that, when the [KEY] button is pressed and lights
in green, “SDI2” is selected for the key source signal.
At this time, combination data indicating that the key fill
signal is “SDI1” and the key source signal is “SDI2” is
recorded on the unit.
After the key fill signal and key source signal have been
switched to other signals to perform another operation, if
the key fill signal is then selected and set to “SDI1”, the
saved combination data causes the key source signal to
automatically switch to “SDI2”.
If the key source signal is changed while the key fill
signal is set to “SDI1”, the combination data is updated
to reflect the change, and is recorded on the unit.

<Source To Fill>
When the key source signal is selected, the key fill
signal switches automatically.
(The [KEY] button first lights amber.)

The initial values for the key source signal and the key fill
signal are the same.

Setting the fill matte color

1

Press the

KEY1

CKEY

button to light its indicator, and display

the Key menu.

2

Use [F1] to display the Fill Matte sub menu.

3

Use [F2], [F3] and [F4] to adjust the Hue, Sat and Lum
of the fill matte.

w

To call the preset color

Use [F5] to select the preset color using the Load item,
and press the [F5].

p

When [F5] is pressed, what has been set so far is
canceled and replaced with the preset color values.

p

To save the values that were set before calling the preset
color, refer to “Memory”.