Inquiry, Inquiry_cancel, Periodic_inquiry_mode – Teledyne LeCroy Merlins Wand - Users Manual User Manual
Page 106: Inquiry inquiry_cancel periodic_inquiry_mode
90
CATC M
ERLIN
’
S
W
AND
2.00
C
HAPTER
A
User’s Manual
Command Generator Command Descriptions
Inquiry
Inquiry will cause Merlin’s Wand to enter Inquiry mode and discover other
nearby Bluetooth devices.
Inquiry_Cancel
Inquiry_Cancel will cause Merlin’s Wand to stop the current Inquiry if the
Bluetooth device is in Inquiry mode.
Periodic_Inquiry_Mode
Periodic_Inquiry_Mode is used to configure Merlin’s Wand to perform a
periodic Inquiry based on a specified period range.
Note
: Max_Period_Length > Min_Period_Length > Inquiry Length.
Command Parameters
Examples
Comments
Inquiry_Length
8
Num_Responses
10
Return Events
Inquiry_Complete
Inquiry_Result
Inquiry_Error
Command Parameters
Examples
Comments
N/A
Return Events
Inquiry_Canceled
Inquiry_Error
Command Parameters
Examples
Comments
Max Period Length
10
Range: 0x03 – 0xFFFF
Min Period Length
9
Range: 0x02 – 0xFFFE
Inquiry Length
8
Range: 0x01 – 0x30
Num of Responses
10
Range: 0-255 (0=Unlimited
number of responses)
Return Events
Periodic_Inquiry_Mode_Complete
Periodic_Inquiry_Mode_Error