Hciwritevoicesettings(), C.5 obex commands, Obexclientabort() – Teledyne LeCroy Merlins Wand - Users Manual User Manual
Page 228: Obex commands
212
CATC M
ERLIN
’
S
W
AND
2.00
C
HAPTER
C
User’s Manual
Merlin’s Wand Scripting Commands
HCIWriteVoiceSettings()
HCIWriteVoiceSettings(Address, VoiceSetting)
Return value
•
“Success”
•
“Failure”
•
“Timed Out”
•
“Failed: Device not found”
•
“Not connected”
Comments
Attempts to write the voice settings for the specified address. A connection
must be established before voice settings can be written.
Example
result = HCIWriteVoiceSettings('6E8110AC0108', 0x0060);
Trace("HCIWriteVoiceSettings() returned: ", result,
"\n\n");
C.5 OBEX Commands
OBEXClientAbort()
Return value
•
“ClientAbort Complete”
•
“ClientAbort Error”
Parameter
Meaning
Default Value
Comments
Address
Bluetooth
address of
device whose
voice settings
to write
VoiceSetting
Three-digit
hex value con-
taining the
voice settings
Possible values:
0x0060=CVSD coding
0x0061=u-Law coding
0x0062=A-law coding
Parameter
Meaning
Default Value
Comments
N/A