Disconnect(), Doinquiry(), Disconnect() doinquiry() – Teledyne LeCroy Merlins Wand - Users Manual User Manual

Page 173

Advertising
background image

157

CATC M

ERLIN

S

W

AND

2.00

C

HAPTER

C

User’s Manual

Merlin’s Wand Scripting Commands

Example

result = Connect(Devices[0]);

if(result != "Success")

{

MessageBox("Failed to connect!");

}

Disconnect()

Disconnect(Address)

Return value

“Success”

“Failure”

“Timed out”

Comments

Closes the ACL connection with the specified device

Example

result = Disconnect(Devices[0]);

if(result != "Success")

{

MessageBox("Failed to disconnect!");

}

DoInquiry()

DoInquiry(IAC, Timeout)

Parameter

Meaning

Default Value

Comments

Address

Bluetooth

address of

device to con-

nect with

Parameter

Meaning

Default Value

Comments

IAC

Inquiry

Access Code

GIAC

“GIAC”, or a 32-bit integer value

Timeout

Timeout in

units of 1.2

seconds

5

Advertising