Read_voice_setting, Reset, Set_event_filter – Teledyne LeCroy Merlins Wand - Users Manual User Manual

Page 119: Read_voice_setting reset set_event_filter

Advertising
background image

103

CATC M

ERLIN

S

W

AND

2.00

C

HAPTER

A

User’s Manual

Command Generator Command Descriptions

Read_Voice_Setting

Read_Voice_Setting will read the values for the Voice_Setting parameter in
Merlin’s Wand, which controls all the various settings for the voice
connections.

Reset

Resets the Bluetooth Host Controller, Link Manager, and the radio module
of Merlin’s Wand. After executing this command, the application has to be
restarted.

Set_Event_Filter

Set_Event_Filter is used by the Host to specify different event filters. The
Host may issue this command multiple times to request various conditions
for the same type of event filter and for different types of event filters.

Command Parameters

Examples

Comments

N/A

Return Events

Read_Voice_Setting_Complete

Read_Voice_Setting_Error

Command Parameters

Examples

Comments

N/A

Will reset to default values
for the parameters

Return Events

Reset_Complete

Command Parameters

Examples

Comments

FilterType

0x00

0x00=Clear All Filters

0x01=Inquiry Result

0x02=Connection Setup

FilterConditionType

0x00

0x00=New device
responded to the Inquiry
process

0x01= Device with a
specific Class of Device
responded to the Inquiry
process.

0x02=Device with specific
BD_ADDR responded to
the Inquiry process.

Advertising