B.14 obex client connection and client get & put, Procedure, Obex client connection and client get & put – Teledyne LeCroy Merlins Wand - Users Manual User Manual

Page 169: Click the obex tab to display the obex menu, Select clientconnect from the menu

Advertising
background image

153

CATC M

ERLIN

S

W

AND

2.00

C

HAPTER

B

User’s Manual

Command Generator Examples

B.14 OBEX Client Connection and Client Get & Put

Procedure

In this scenario, Merlin’s Wand forms a client connection with the target
device and then retrieves a text file from the target and sends one to it.

This procedure assumes that an ACL connection has been established (see
“Establish Baseband Connection” on page 139). It also assumes that the
target device has been configured as an OBEX server.

Note

: When the OBEX window is first opened, Merlin’s Wand will automatically run an

OBEX_ClientInit command and initiate itself as an OBEX client. This means that
you do not have to manually execute a ClientInit command at the start of this
procedure.

Step 1

Click the OBEX tab to display the OBEX menu.

Step 2

Select ClientConnect from the menu.

Step 3

Select the target device from the BD_ADDR parameter
menu.