Command Generator Examples

B.1 Device Discovery and Remote Name Request

Procedure

In this scenario, Merlin’s Wand performs a General Inquiry and a Remote
Name Request.

Step 1

Select HCI tab.

Step 2

Select Inquiry from the menu. You can use the default settings for
the Inquiry_Length (8 seconds) and Num_Responses (10).

Step 3

Click Execute.

The Event Log should display an Inquiry_Result for each found device
followed by an Inquiry_Complete event.

Step 4

Select Remote_Name_Request from the menu. Select the
target device from the BD ADDR drop-down menu. You can
use the default settings for the other drop-down menus.

Step 5

Click Execute.

The target device should then respond to the command with its name.