Write_pin_type – Teledyne LeCroy Merlins Wand - Users Manual User Manual

Page 124

Advertising
background image

108

CATC M

ERLIN

S

W

AND

2.00

C

HAPTER

A

User’s Manual

Command Generator Command Descriptions

Write_Page_Timeout

Write_Page_Timeout command will write the value for the
Page_Reply_Timeout configuration parameter, which allows Merlin’s
Wand to define the amount of time a connection request will wait for the
remote device to respond before the local device returns a connection
failure.

Write_PIN_Type

Write_PIN_Type will specify whether the Host supports variable PIN or
only fixed PINs.

Command Parameters

Examples

Comments

Timeout

0x10

0=Illegal Page Timeout.
Must be larger than 0

N = 0xXXXX Page
Timeout measured in
Number of Baseband slots.

Interval Length = N * 0.625
msec (1 Baseband slot)

Range for N: 0x0001 –
0xFFFF

Time Range: 0.625 msec
-40.9 Seconds

Default: N = 0x2000 Time
= 5.12 Sec

Return Events

Write_Page_Timeout_Complete

Write_Page_Timeout_Error

Command Parameters

Examples

Comments

PIN_Type

0

0x00=Variable PIN
0x01=Fixed PIN

Return Events

Write_PIN_Type_Complete

Write_PIN_Type_Error