Using Merlin to Record Merlin’s Wand Traffic

8. Using Merlin to Record Merlin’s

Wand Traffic

It’s possible to control the CATC Merlin Bluetooth Protocol Analyzer via
Merlin’s Wand. The two can be used together to capture real-time test
sequence results, as is required by the Bluetooth SIG to provide evidence of
product compliance to the specification.

Merlin's Wand has built-in functionality for controlling the Merlin protocol
analyzer. Through Merlin's Wand, a Bluetooth recording session can be set
up on Merlin, even if the Merlin application runs on a remote computer.

8.1 Set Up a Remote Machine

If Merlin’s Wand will be used to run Merlin on a remote machine, DCOM
and accessibility properties on the remote machine must be properly
configured. The configuration procedures differ slightly for different
operating systems.

Note

: If Merlin’s Wand will be used only to run Merlin on the same computer that is

running Merlin’s Wand, skip to “Connect to Merlin with Merlin’s Wand” on
page 79
.

Windows 98/Me Operating Systems

Use this procedure to configure DCOM properties to run a Merlin analyzer
remotely on a machine running Windows 98 or Windows Me. All the steps
should be performed on the remote machine.

Step 1

Open the Merlin application on the remote machine in
order to register it with COM, and then close the application.

Step 2

Download and install dcom98.exe and dcm95cfg.exe
DCOM configuration utilities from Microsoft. They are
available via the following links:

http://download.microsoft.com/msdownload/dcom/98/x86/en/dcom98.exe

http://download.microsoft.com/msdownload/dcom/98/x86/en/dcm95cfg.exe

Step 3

Select Start > Run from the Windows taskbar.

The Run dialog will open.

Step 4

Enter “dcomcnfg” in the Open combo box and press OK.

The Distributed COM Configuration Properties dialog will open.