203
CATC M
ERLIN
’
S
W
AND
2.00
C
HAPTER
C
User’s Manual
Merlin’s Wand Scripting Commands
HCISniffMode()
HCISniffMode(Address, MaxInterval, MinInterval, Attempt,
Timeout)
Return value
•
“Success”
•
“Failure”
•
“Failed: Device not found”
•
“Not connected”
Comments
Enters Sniff mode with parameters as specified.
Example
Device = '010203040506';
result = HCISniffMode(Device, 0xFFFF, 100, 0x3FF6, 0x7FFF);
Trace("HCISniffMode result is: ", result, "\n");
Parameter
Meaning
Default Value
Comments
Address
Bluetooth
address of
device in
question
MaxInterval
Maximum
number of
0.625-msec
intervals
between sniff
periods.
Range is 0x0001 to 0xFFFF
(0.625 msec to 40.9 sec).
MinInterval
Minimum
number of
0.625-msec
intervals
between sniff
periods.
Range is 0x0001 to 0xFFFF
(0.625 msec to 40.9 sec).
Attempt
Number of
receive slots
for sniff
attempt.
Range is 0x0001 to 0x7FFF
(0.625 msec to 20.5 sec).
Timeout
Number of
receive slots
for sniff time-
out.
Range is 0x0001 to 0x7FFF
(0.625 msec to 20.5 sec).