Hcisniffmode(), Enters sniff mode with parameters as specified – Teledyne LeCroy Merlins Wand - Users Manual User Manual

Page 219

Advertising
background image

203

CATC M

ERLIN

S

W

AND

2.00

C

HAPTER

C

User’s Manual

Merlin’s Wand Scripting Commands

HCISniffMode()

HCISniffMode(Address, MaxInterval, MinInterval, Attempt,
Timeout)

Return value

“Success”

“Failure”

“Failed: Device not found”

“Not connected”

Comments

Enters Sniff mode with parameters as specified.

Example

Device = '010203040506';

result = HCISniffMode(Device, 0xFFFF, 100, 0x3FF6, 0x7FFF);

Trace("HCISniffMode result is: ", result, "\n");

Parameter

Meaning

Default Value

Comments

Address

Bluetooth

address of

device in

question

MaxInterval

Maximum
number of

0.625-msec

intervals

between sniff

periods.

Range is 0x0001 to 0xFFFF
(0.625 msec to 40.9 sec).

MinInterval

Minimum

number of

0.625-msec

intervals

between sniff

periods.

Range is 0x0001 to 0xFFFF
(0.625 msec to 40.9 sec).

Attempt

Number of

receive slots

for sniff
attempt.

Range is 0x0001 to 0x7FFF
(0.625 msec to 20.5 sec).

Timeout

Number of

receive slots

for sniff time-

out.

Range is 0x0001 to 0x7FFF
(0.625 msec to 20.5 sec).