ADS Environmental Services IETG FlowHawk QR 775012 A4 User Manual

Page 101

Advertising
background image

3-42 IETG FlowHawk Manual

8. Spot drill the pipe wall through the hole, install a M6 x 55-mm

anchor bolt, and secure the band to the anchor bolt with a
washer and nut.

Note: Make sure the submerged portion of the band is
flush with the pipe wall. If it is not, remove the band and
conform the band to the pipe.

9. Install a M6 x 55-mm anchor bolt, washer, and nut below the

flow surface 30 to 80 mm away from the Peak Combo Sensor
or Slimline Peak Combo Sensor on each side. This will hold
the sensor securely against the pipe wall and prevent the end of
the band from twisting in the flow or catching debris.

10. Conform the portion of the band above the flow surface to the

pipe wall, and install an M6 x 55-mm anchor bolt, nut, and
washer every 305 to 610 mm up to the top of the band.

Completed ½-band mount in pipe

11. Measure the physical offset for the sensor by manually

measuring the depth of the flow from the bottom of the pipe to
the flow surface and then measuring the distance from the nose
(i.e., front end at the pipe surface) of the sensor to flow
surface. Subtract the second measurement from the initial
depth of flow to determine the physical offset.

Advertising